TM 5-3610-286-20
2-74.
Deflector Safety Limit Switch (cont).
c. Aline. (figure 2-200)
NOTE
Safety limit switches on printing press open (or close) contacts after switch
plunger is depressed (or not depressed). Plunger travels 1 mm between
opening and closing of contacts regardless of the type of actuator or push rod
that presses or releases the plunger. Mounting screws are the same for all
(1)
(2)
(3)
(4)
switches.
Loosen two screws (1).
Using feeler gage, aline plunger to allow
Tighten two screws (1).
Recheck measurement with feeler gage.
1 mm space between plunger (2) and lever (3).
2-408