TM 5-3610-286-20
2-68.
Electromagnetic Switch.
This task covers:
a. Test
b. Remove
c. Install
d. Adjust
INITIAL SETUP
Tools
Retaining-ring pliers
5 mm hex key
6 mm hex key
8 mm combination wrench
13 mm combination wrench
0.5 x 3.5 x 100 mm flat-tip screwdriver
Combination pliers
Feeler gage
Equipment Conditions
Lower guard and accessories removed (para. 2-19)
Additional Personnel Requirement
Electrician MOS 35E20
a. Test. Test switch in accordance with the instructions given in para. 2-10, Troubleshooting.
b. Remove. (figure 2-162)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Twist collar on cable (1) to loosen. Tag wires for position identification and disconnect
them from magnet (2).
Remove two cap screws (3), two flat washers (4), and two nuts (5).
Pull out cotter pin (6). Remove pin (7), two flat washers (8), and magnet (2).
Remove two cap screws (9), two ribbed washers (10), and fixing plate (11).
Remove stud (12) from stop lever (13). Remove retaining ring (14) and flat washer (15)
from stud.
Remove pull rod (16).
Remove stop bolt (17) and shock absorber (18).
Remove cap screw (19), fiat washer (20), and guide plate (21).
Remove retaining ring (22) from stud (23). Remove flat washer (24), two needle bushings
(25), and stop lever (13).
Remove nut (26), flat washer (27), and stud (23).
2-358