TM 5-3610-286-20
2-28.
Journal Box Housing Assembly.
This task covers:
a. Remove
b. Repair
c. Install
INITIAL SETUP
Tools
Equipment Conditions
5 mm hex key
Main guard assembly (O/S) removed
6 mm hex key
(para. 2-20)
11 mm combination wrench
Inking form rollers removed
13 mm combination wrench
(TM 5-3610-286-10)
3 mm pin punch
Ink oscillator rollers removed (coupling type -
8 mm pin punch
TM 5-3610-286-10, solid type, para. 2-33)
Ball-peen hammer
Roller Guide Rail Assemblies (para. 2-25)
a. Remove. (figure 2-47).
NOTE
Procedure iS for journal box housings 0303 and 0305, (the housing on
D/S closest to delivery end of press). Procedure for journal box
housings 0304 and 0306, (journal box nearer to feeder end), is similar
except these journal box housings must be removed from feeder end of
press.
Journal box housings on O/S are removed with the swivel lever assemblies
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
2-136
(para. 2-27).
Loosen lock nut (1) and remove spring rod (2), spring (3) and nut (1).
Remove rod head (4), retaining ring (5), washer (6), and pin (7).
Remove lubrication line (8).
Remove three socket-head screws (9) and bearing (10).
Remove journal box housing (11), spacers (12), journal box housing (13), retaining
ring (14), and gasket (15).
Remove three socket-head screws (16), bearing (17) and gaskets (18).
Remove hex-head screw (19) and journal box (20).
Remove two socket-head screws (21), two washers (22), worm gear housing (23), worm
gear (24), and spacer (25).