Figure 2-10.
TM 5-3610-286-20
2-16
Ink Fountain Guard Safety Limit Switch (cont).
c. Install. (figure 2-10)
(1) Install limit switch (1) and two slotted screws (2).
(2) Install cable (3) into limit switch (1) and twist on cable collar (4).
(3) Install leads (5) and tighten two cross-head terminal screws (6).
(4) Close the hinged cover (7). Tighten two screws (8).
(5) Aline limit switch (para. d).
2-68