TM 5-3610-285-14
Table 7-3. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ERRATIC OPERATION OF DIGITAL DISPLAY.
Step 1. Check for defective controls.
(a) If controls not defective, proceed to step 2.
(b) If controls defective, replace controls (paragraph 7-16.7 or 7- 16.10).
Step 2. Check for defective filter.
(a) If filter not defective, notify supervisor.
(b) If filter defective, replace filter (paragraph 7-16.3).
5. TRANSMISSION PROBE LAMP WILL NOT ENERGIZE.
Step 1. Check for power at outlet.
(a) If power present, proceed to step 2.
(b) Restore power to outlet.
Step 2. Check for defective power cord.
(a) If power cord not defective, proceed to step 3.
(b) If power cord defective, replace power cord (paragraph 7- 16.11).
Step 3. Check for defective fuse.
(a) If fuse not defective, proceed to step 4.
(b) If fuse defective, replace fuse.
Step 4. Check for defective ON/OFF switch.
(a) If ON/OFF switch not defective, proceed to step 5.
(b) If ON/OFF switch defective, replace power switch (paragraph 7- 16.15).
7-31