TM 5-3610-285-14
f.
Release spring closure and remove defective motor/pump assembly from housing.
g.
Remove O-ring from lower groove in column.
h.
Install new O-ring to lower column groove in new motor/pump assembly.
i.
Install new motor/pump assembly to housing and retain with spring closure.
j.
Reconnect motor power cord to processor control panel.
k.
Reinstall pump splash cover, top cover and left access panel.
l.
Close drain valve.
m.
Service processor tank.
n.
Turn on processor circuit breaker.
5-215