TM 5-3610-285-14
Table 5-6. DIRECT/GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
FILM DOES NOT TRAVEL THROUGH SQUEEGEE ASSEMBLY.
Check for damaged rollers in crossover.
Remove, inspect, and repair crossover assembly as necessary (paragraph 5-20.2).
2.
REPLENISHER PUMP OPERATES BUT DOES NOT MOVE LIQUID.
Check for damaged impeller in pump.
Remove, inspect, and repair pump as necessary (paragraph 5-20.3).
3.
DEVELOPER OR FIXER RECIRCULATION PUMP OPERATES BUT DOES NOT MOVE LIQUID.
Check for damaged pump.
Remove, inspect, and repair pump as necessary (paragraph 5-20.4).
4.
FILM DOES NOT TRANSPORT CORRECTLY THROUGH RACK ASSEMBLIES.
Check for damaged rack.
Remove, inspect, and repair rack assembly as necessary (paragraph 5-20.5 for developer rack or
paragraph 5-20.6 for fixer or wash rack).
5-20. MAINTENANCE PROCEDURES.
a.
This section contains instructions covering direct/general support maintenance functions for the film
processor. Personnel required are listed only if the task requires more than one.
b.
After completing each maintenance procedure, perform operational check to be sure that equipment is
properly functioning.
5-202