TM 5-3610-285-14
Table 5-2. TROUBLESHOOTING - Cont
MALFUNCTI ON
TEST OR INSPECTION
CORRECTIVE ACTION
2.
DRYER FAN DOES NOT BLOW AIR - Cont
(a)
If intake filter is clogged, replace intake filter (paragraph 5-10.3).
(b)
If malfunction persists, refer to organizational maintenance.
3.
RECIRCULATING PUMPS DO NOT OPERATE WHEN FILM IS FED INTO PROCESSOR.
Step 1. Check that MAIN DRIVE switch is ON.
(a)
If MAIN DRIVE switch is ON, proceed to step 2.
(b)
If MAIN DRIVE switch is OFF, turn on switch.
Step 2. Check that DRYER and DEV.HEAT switch is ON.
(a)
If DRYER and DEV.HEAT switch is OFF, turn on switch.
(b)
If malfunction persists, refer to organizational maintenance.
4.
RECIRCULATED WASH WATER DOES NOT ENTER PROCESSOR.
Step 1. Check that RECIRC PUMP switch is ON.
(a)
If RECIRC PUMP switch ON, proceed to step 2.
(b)
If RECIRC PUMP switch is not ON, turn on switch.
Step 2. Check that position of WATER SUPPLY valve is in pump position.
(a)
If in pump position, proceed to step 3.
(b)
If not in pump position, rotate WATER SUPPLY valve to pump position.
Step 3. Check for clogged recirculation hoses.
(a)
If hoses are clogged, clean hoses.
(b)
If hoses are not clogged, replace recirculation filter (paragraph 5-10.6).
5-67