TM 5-3610-285-14
Table 5-2. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ROLLERS DO NOT ROTATE WHEN DRIVE SWITCH IS TURNED ON - Cont
Step 4. Check that toothed gears on rack assemblies are properly meshed.
(a) If gears are alined correctly, proceed to step 5.
(b) If gears are misalined, reposition rack assemblies.
Step 5. Check that drive chain is properly positioned.
(a) If drive chain is misalined, reposition drive chain.
(b) If malfunction persists, refer to organizational maintenance.
2. DRYER FAN DOES NOT BLOW AIR.
Step 1. Check that DRYER and DEV. HEAT switch is ON.
(a) If DRYER and DEV. HEAT switch is ON, proceed to step 2.
(b) If DRYER and DEV. HEAT switch is OFF, turn on switch.
Step 2. Check for clogged air intake filter.
5-66