TM 5-3610-285-14
d.
Remove tape from bolt connectors under blowers and tag and disconnect wires from defective blower(s).
e.
Remove four mounting nuts attaching blower(s) to mounting plate.
f.
Carefully remove defective blower(s) from mounting plate; then remove four spacers.
g.
Ensure that four spacers are installed over stud posts; then carefully install new blower(s) onto mounting
plate.
3-31