TM 5-3610-285-14
Table 3-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
ITEM TO BE INSPECTED
For Readiness
IN
Reporting
ITEM
TER-
PROCEDURE
Equipment Is
NO.
VAL
Not Ready/
Available If:
PLATE FINISHING TABLE-Cont
1
B/D
Inspect-Cont
5.
Place blowers/heater switch to right and
Blowers fail to
verify blowers turn on and heat is
operate and/or
produced.
heat is not
produced.
6.
Place blowers/heater switch to-center
Blowers remain
position and verify blowers and heater
on and/or heat-
turn off.
er does not
turn off.
7.
Inspect paper roll and verify sufficient
Quantity of
kraft paper is available.
paper insuffi-
cient.
2
B/A
Clean.
WARNING
Death or serious injury may occur from electrical shock unless power
cord is unplugged before servicing.
1.
Place blowers/heater switch to center position.
3-8