TM 5-3610-259-14
h. Reconnect wires using bolt connectors under blowers, and retape bolt
connectors.
NOTE
It may be necessary to remove blower/heater housing front cover plate to
properly aline blowers exhausts.
3-16.5
i.
Carefully reinstall blowers and blowers mounting plate so that blowers
exhausts fit through portal holes of frame, and screw holes on top
aline.
j.
Reinstall pencil tray and blowers/heater housing front cover panel if
removed.
k. Plug in power cord.
Replace Power Cord.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS :
Tool Kit, Light Machine Repair
Flat Tip Screwdriver
7/16 in. Combination Wrench
SUPPLIES: Power Cord
Electrical Tape (Item 50, Appendix E)
Death or serious injury may occur from eletrical shock unless power cord is
unplugged before servicing;
a.
Unplug power cord.
WARNING
3-32