TM 5-3610-259-14
Section III. OPERATOR MAINTENANCE
3-8. LUBRICATION INSTRUCTIONS. This equipment does not require lubrication at the
operator level of maintenance.
3-9. TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during the
operation or maintenance of the plate finishing table, or its components.
You
should perform the test/inspections and corrective actions in the order listed.
b. This manual cannot list all malfunctions that may occur, nor all test or
inspections and corrective actions.
If a malfunction is not listed or is not
corrected by listed corrective actions, notify your supervisor.
Table 3-2.
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. PLATE FINISHING TABLE WILL NOT ENERGIZE.
Step 1.
Check that power cord is plugged in.
(a) If power cord is plugged in, proceed to step 2.
(b) Plug in power cord.
Step 2.
Check position of power panel circuit breaker.
(a) Reset circuit breaker.
(b) If problem persists, notify your supervisor.
3-100 MAINTENANCE PROCEDURES.
a.
This section contains instructions covering operator maintenance functions
for t he plate finishing table.
Personnel required are listed only if the task
requires more than one.
b. After completing each maintenance procedure, perform operational check to be
sure that equipment is properly functioning.
PROCEDURE
INDEX
PARAGRAPH
Replace Kraft Paper Roll . . . . . . . . . . . . . . . . . . . . . . . .
3-10.1
3-12