TM 5-3610-259-14
WARNING
Voltages that are capable of causing death may be stored in capacitors after
power is removed.
Ground and discharge capacitors to zero volts before
disconnecting capacitor leads.
Personal injury or death may occur from failure
to do SO.
c.
Tag and disconnect wires from capacitors.
Capacitor bottom connector is
the negative connector.
d. Remove nuts and washers from studs for holddown brackets that hold top
two capacitors.
NOTE
If one of the top two capacitors is being replaced, proceed to step f.
e.
Remove nuts and washers from studs for holddown brackets that hold
bottom two capacitors.
f. Remove defective capacitor from housing.
If one
g.
h.
i.
j.
k.
of the top two capacitors
NOTE
were replaced, proceed to step h.
Install new capacitor into housing and reinstall holddown brackets for
capacitors.
Install new capacitors into housing and reinstall holddown brackets
for top capacitors.
Reconnect wires to capacitors.
Reinstall lower cabinet panel.
Turn on power panel circuit breaker.
2-59