TM 5-3610-259-14
c.
Remove main power contactor cover.
d. Tag and disconnect wires from main power contactor.
e.
Remove two screws on bracket and remove bracket with contactor attached.
f. Remove insulator and defective main power contactor
bracket.
9.
Install new main power contactor and insulator onto
from mounting
mounting bracket.
h. Reinstall
i.
Reconnect
j.
Reinstall
contactor and mounting bracket into housing.
wire to new contactor.
main power contactor cover.
k. Rotate glass frame into horizontal position and lock into place with
frame release knob.
l.
Turn on power panel circuit breaker.
2-61