TM 5-3610-259-14
W A R N I NG
3.
4.
5.
6.
7.
8.
9.
DRY CLEANING SOLVENT, P-D-680, USED TO CLEAN PARTS
IS POTENTIALLY DANGEROUS TO PERSONNEL AND PROPERTY.
AVOID REPEATED AND PROLONGED SKIN CONTACT. WEAR
SOLVENT IMPERMEABLE GLOVES AND EYE/FACE PROTECTIVE
EQUIPMENT WHEN USING SOLVENT. DO NOT USE NEAR OPEN
FLAME OR EXCESSIVE HEAT. FLASH POINT OF SOLVENT IS
100°F TO 138°F (38°C TO 59°C).
Remove defective gasket by prying entire gasket from door. Scrape
all traces of gasket and adhesive from door.
Wash with solvent.
Coat gasket seating area on door with adhesive.
Firmly press new gasket onto door.
Wipe excess adhesive from gasket.
Close door and latch firmly.
Open door and wipe excess adhesive from frame and door.
Allow adhesive to cure before using door.
1.5.3.2
REPLACE PERSONNEL/CARGO DOOR.
TOOLS: Tool Kit
Rivet Gun
Drill and Bits
Hoist
Paint Brushes
SUPPLIES: Door
Rivets
Gasket
Paint
Adhesive
Cloth
W A R N I NG
TO PREVENT PERSONAL INJURY DO NOT ATTEMPT TO REMOVE
DOOR UNLESS SUITABLE LIFTING EQUIPMENT IS AVAILABLE.
NOTE
Procedures for replacement of large cargo door
at rear and smaller personnel doors differ only
in method of attaching hinges to door.
Both
types of doors are covered in this procedure as
damage to one door type normally will cause
other openings in van body to be damaged.
1-112