TM 5-3610-257-14
Table 1-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES
B- Before
W- Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
IN
FOR READINESS
ITEM TER
ITEM TO BE INSPECTED
REPORTING
NO.
VAL
PROCEDURES
EQUIPMENT IS
NOT READY /
AVAILABLE IF:
VAN BODY - Cont
2
B
Inspect Interior - Cont
S
14.
Inspect eyewash station. Check that eyewash
bottle is in place and full of solution.
B
15.
Inspect blackout curtains.
a.
Inspect blackout curtains and valances for
tears, missing hooks, or broken eyelets.
b.
Inspect nylon hook and pile tape on curtain
and wall for security of attachment.
3
Inspect Air Conditioner. Refer to TM 5-4120-367-14
for preventive maintenance checks and services.
4
M
Service Power Cable.
WARNING
Power cable must be deenergized before
servicing. Death or serious injury may
occur from failure to observe this safety
precaution.
1.
Turn off safety switch.
2.
Disconnect cable from power and communications
panel.
3.
Wrap any cuts or abrasions in cable with electrical
Power Cable
insulation tape.
Damage.
4.
Reconnect power cable to power and communications
panel.
1-29