TM 5-3610-257-14
Table 6-3. ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES
B- Before
W- Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
IN
ITEM TER
ITEM TO BE INSPECTED
NO.
VAL
PROCEDURES
FILM DRYER - Cont
1
S
Service Film Dryer - Cont
28.
Reinstall bottom roller assembly.
29.
Slide gear motor and bracket left to engage gear coupling. Tighten mounting screws.
30.
Reinstall top roller assembly and secure with screws.
31.
Reinstall left side cover and secure with screws.
32.
Reinstall right side cover and secure with screws.
33.
Replace drip tray and plug in power cord.
6-15.
ORGANIZATIONAL TROUBLESHOOTING PROCEDURES
a.
Organizational troubleshooting procedures cover the most common malfunctions that may be repaired at the
organizational level. Repair or adjustment requiring specialized equipment is not authorized unless such equipment is
available. Troubleshooting procedures used by the operator should be conducted in addition to the organizational
troubleshooting procedures.
b.
This manual cannot list all the possible malfunctions or every possible test/inspection and corrective action. If a
malfunction is not listed or is not corrected by a listed corrective action notify your supervisor.
c.
For unidentified electrical malfunctions, refer to schematic on page 6-4 for fault analysis.
d.
If the film dryer does not power up when turned on, verify that 120 V ac is present at the receptacle. If voltage is
not present, plug equipment into receptacle with power available and proceed with equipment troubleshooting. Perform no
power troubleshooting procedures for dead receptacle (Table 1-4).
6-23