TM 5-3610-257-14
Table 3-1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES
NOTE
If the equipment must be kept in continuous operation, check and service only those items that
can safely be checked and serviced without disturbing operation. Make the complete checks and
services when the equipment can be shut down.
B- Before
W- Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
IN
FOR READINESS
ITEM TER
ITEM TO BE INSPECTED
REPORTING
NO.
VAL
PROCEDURES
EQUIPMENT IS
NOT READY /
AVAILABLE IF:
LIGHT INTEGRATING EXPOSURE CONTROL INSTRUMENT
1
B
Inspect.
1.
Remove exposure control instrument power cord
from outlet.
2.
Inspect power cord for cuts, breaks, broken plug,
Power cord
and other signs of damage.
has cuts,
breaks, or
broken plug.
3.
Remove remote and multicolor phototube control
cords from exposure control instrument.
4.
Inspect cords for cuts, breaks, broken plug or
Cord(s) has
pins, and other signs of damage.
cuts,
broken plug
or pins.
5.
Inspect exterior of exposure control instrument,
Broken or
remote control station, multi color phototube unit,
missing
and multi color phototube switch for dents, scratches,
parts/components.
broken or missing parts/components.
3-13