TM 5-3610-253-14
Install new switch and spacer board but do not tighten screws.
e.
f. Adjust switch by moving appropriate knob control in or out the maximum
distance. Then move switch until nylon cam activates switch. Tighten
switch mounting screws.
Reconnect wires.
g.
h. Reinstall backgauge control switch cover.
Place operator key back into safety lock.
i.
5-40.39 Replace Backgauge Limit
Switches.
MOS: 35E, Special Electronic Devices Repairer
Flat Tip Screwdriver
TOOLS:
No. 2 Cross Tip Screwdriver
SUPPLIES: Switch
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
Turn off power.
a.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock safety lock and keep key in your
b. Remove oil drip pans under backgauge table.
5-585