TM 5-3610-253-14
Secure MC unit in place with top retaining screws.
z.
aa.
Carefully install ML circuit board and secure in place with locking pins.
ab.
Reconnect ribbon cable to MC unit and lock in place with locking tabs.
ac.
Reinstall front electronics enclosure cover.
ad.
Place operator key back into safety lock.
5-40.36 Replace MC Unit Electronic
Relays
MOS: 35E, Special Electronic Devices Repairer
TOOLS: Flat Tip Screwdriver
7 mm Nut Driver
SUPPLIES: Electronic Relay
WARNING
Death or serious injury may occur from electrical shock unless power is
turned off before servicing.
a.
Turn off power.
(1) Turn Star-Delta switch to Y position, then to O position.
(2) Turn main power switch to O position.
(3) Using operator key, lock safety lock and keep key in your
b. Remove front electronics enclosure cover.
5-580