TM 5-3610-253-14
Table 5-21. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
16. ONLY ONE OCL LAMP COMES ON - Cont
Step 1.
(a) If fuse open, replace defective fuse.
(b) If malfunction persists, refer to electrical schematic
and troubleshoot.
17. BACKGAUGE DOES NOT OPERATE ELECTRICALLY.
Step 1.
Remove backgauge V-belt cover and check for motor operation.
(a) If motor operates, adjust or replace V-belts (paragraph
(b) If motor does not operate, proceed to step 2.
Step 2.
Check to see that backgauge motor overload relay is on (I), and not
tripped.
If relay trips again, proceed to step
(a) Reset overload relay.
5.