TM 5-3610-253-14
Sequence
Step
Basic Operation Circuit/Component Operation
NOTE
All LED indications are in reference to the LEDs on the hardware channel
(HK) board unless otherwise stated.
1
Cut permission from positioning computer (AR). Backgauge
stopped. LED V3 on.
2
Press both cutting buttons within 0.5 seconds. LED V6 and
V7 off, LED V8 and V9 on. LED V14 on. Clamp locking valve
(M1) energized, clamp lowers.
3
Light barrier test demanded by positioning computer (AR).
(LEDs on left light barrier housing: V8 shortly off while
V10 shortly on) If light barrier test positive LED V18
on.
4
Energize clamping valve (M2) LED V17 on.