TM 5-3610-253-14
e.
Remove retaining screw.
f. Remove fixed wire grip from grip holder.
Examine fixed wire grip saw teeth. If only one side is worn, turn
g.
fixed grip over so that fresh saw teeth face wire. If both sides
are worn, replace with new grip.
h. Reinstall wire grip in grip holder.
i.
Reinstall retaining screw and tighten screw.
Replace grip spring on movable wire grip.
j.
If force is used in closing stitcher head door, the stitcher will be
damaged. If door binds, manually depress supporter until the swivel
clears supporter and the door will close.
k. Rethread wire if necessary. Release pawl and rotate pulley to the
right. Check that head operates freely.
l.
Replace rear belt guard and tighten screw.
CAUTION
Stitcher mechanism may be damaged if force is used to open or close
stitcher head door.
m.
Close stitcher head door.
n.
Plug in power cord.
3-32