TM9-4931-436-14&P
Device,
Alignment
Direct Support Troubleshooting Table - continued
Table 5-1.
TEST OR INSPECTION
CORRECTIVE
ACTION
MALFUNCTION
DEVICE RESPONDS TO
1. Test for defective
1. Replace A2A3.
12.
CODE OTHER THAN 27
board A2A3.
DEVICE UPDATES AIM
1. Test for defective
13.
1. Replace A2A3.
CORRECTION NUMBERS
FASTER THAN EVERY
board A2A3.
2 SECONDS
2. Test for defective
2. Replace A2A2.
timing logic board A2A2.
1. Test for defective
DEVICE UPDATES AIM
14.
1. Replace A2A3.
CORRECTION NUMBERS
SLOWER THAN EVERY
board A2A3.
2 SECONDS
2. Test for defective
2. Replace A2A2.
timing logic board A2A2.
ALL DISPLAYS ARE
1. Test for defective
15.
1. Replace AlA13.
FAULTY
automatic gain control
AlA13.
2. Test for defective
2. Replace A2A4.
output logic board A2A4.
3. Test for defective
3. Replace A2A3.
board A2A3.
16.
DEVICE DOES NOT
1. Test for defective
1. Replace A2Al.
RESPOND TO CODE 27
input board.
OR BORESIGHT CODE.
2. Test for defective
2. Replace A2A2.
timing board.
3. Test for defective
3. Replace A2A3.
5-6