4-1. TROUBLESHOOTING INFORMATION (cont).
SYMPTOM INDEX
Troubleshooting
Procedure
(Page)
M2A2 AIMING CIRCLE
Compass needle fails to turn freely when unlocked . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Image is poorly defined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...4-3
Image is tilted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Parallax in optical system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Reticle does not become illuminated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Reticle is tilted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Telescope reticle has poor definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Table 4-1. GENERAL SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
M2A2 AlMING CIRCLE
1. RETICLE DOES NOT BECOME ILLUMINATED.
Step 1. Attach a serviceable M51 instrument light to the elbow telescope. Turn switch
on.
Step 2. Check for dirt on optical instrument window.
Remove optical instrument window. Refer to page 4-5. Clean
thoroughly using optical lens cleaning compound (item 4, appx D)
Step 3. Check position of reticle assembly.
Adjust position of reticle assembly. Refer to page 4-16.
Step 4. Inspect reticle assembly for defects.
Replace defective reticle assembly. Refer to page 4-5.