ARMY TM 9-1290-262-24&P
MARINE CORPS TM 00476C-24&P
AIR FORCE TO 49A7-3-72/74
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Check for worn or damaged worm shaft. Refer to page 3-12.
Step 4. Check for improperly seated ball socket seat.
Step 5. Check for setscrews that are set to tight against worm shaft cap or ball socket
seat.
Adjust setscrews against worm shaft cap or ball socket seat. Refer
Step 6. Check for loose pin in adapter.
Step 7. Recheck for backlash.
If backlash is still present, notify general support maintenance.
5. BACKLASH PRESENT IN AZIMUTH MECHANISM.
Step 1. Check for loose worm shaft cap.
Step 2. Check for broken spring.
Step 3. Check worm shaft ball for out-of-roundness.
If worm shaft ball is out of round, replace worm shaft. Refer to page
Step 4. Check for worn or damaged worm shaft. Refer to page 3-12.
Step 5. Check for improperly seated ball socket. Refer to page 3-12.