Table 3-1. DIRECT SUPPORT TROUBLESHOOTING (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
M2A2 AIMING CIRCLE (CONT)
7. ELEVATION KNOB HAS LIMITED MOVEMENT.
Step 1. Turn elevation knob to elevate or depress elbow telescope.
Step 2. Check that elbow telescope moves 1130 mils in elevation and 430 mils in
depression.
Step 3. Check for missing or improperly positioned key washers.
Replace or reposition key washers. Refer to page 3-12.
Step 4. Recheck elevation worm shaft for limited movement.
8. ELEVATION MICROMETER SCALE SLIPS.
Step 1. Check that screws are tight.
If screws are tight, loosen screws and adjust micrometer scale dial.
Step 2. Check for stripped threads on screws and in adapter.
9. AZIMUTH MICROMETER SCALE SLIPS.
Step 1. Check that screws are tight.
a. If screws are tight, loosen screws and micrometer scale dial.
b. Adjust scales and tighten screws. Refer to page 3-12.