TM5-6675-326-14
Table 1-2.
Operator Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3 .
BLACKOUT SWITCH DOES NOT OPERATE.
Step 1.
Check position of blackout switch.
Reset switch to ON.
Step 2. Check to see if striker plate touches roller on
m i c r o s w i t c h a c t i v a t i n g b l a c k o u t l i g h t.
Reposition plate up or down until microswitch operates.
Loosen screw to reposition plate.
Secure in position.
1-10 OPERATOR MAINTENANCE PROCEDURES.
This section contains step-by-step instructions covering operator
performed maintenance instructions.
1-10.1 Replace Fluorescent Ceiling Lamp
PERSONNEL REQUIRED:
1 Terrain analyst MOS 81Q
MATERIALS/PARTS: Fluorescent lamp
REMOVAL:
ELECTRICAL SHOCK
S e t c e i l i n g l i g h t s w i t c h a n d c e i l i ng
l i g h t c i r c u i t b r e a k e r t o O F F.
Failure to do so may result in death
o r s e r i o u s i n j u r y.
a.
Turn ceiling light switch OFF.
T u r n c e i l i n g l i g h t c i r c u i t
breaker OFF.
1-30