TM5-6675-326-14
5-12.3 Replace Ballast Transformer - Continued
d.
Remove glass surface and set aside.
e.
Remove screws and back cover panel.
f .
Remove screws and defective ballast transformer.
g.
Disconnect and tag wires from ballast transformer.
INSTALLATION:
a.
Connect wiring on new ballast transformer, and remove tags.
b .
Install new ballast transformer, and secure with screws.
c.
Reinstall back cover panel, and secure with screws.
d.
R e i n s t a l l g l a s s s u r f a c e.
e.
Turn clips 90° to secure glass surface.
f .
Reinstall screws on clips.
Tighten all screws.
g.
Plug in power cord, and turn power ON.
5-13 PREPARATION FOR STORAGE OR SHIPMENT.
In the event that the portable tracing/scribing board must be
removed from the section for repair or replacement, refer to TM 740-90-1
f o r s t o r a g e i n s t r u c t i o n s.
Section V.
DIRECT/GENERAL SUPPORT MAINTENANCE
5-14 There are no assigned direct/general support maintenance tasks for
this equipment.
5-22