2-19.5 Replace Momentary Switch - Continued
REMOVAL:
WARNING
ELECTRICAL SHOCK
Unplug power cord before servicing the split-stage
l i g h t t a b l e . F a i l u r e t o d o s o m a y r e s u l t i n d e a th
o r s e r i o u s i n j u r y.
a. Turn power OFF, and unplug power cord.
b .
Raise optical mount to maximum height.
c .
Remove two cable clamps.
d .
Remove nut.
e. Remove momentary switch and wires by withdrawing through
bottom of optical mount .
f .
Tag wires and desolder from switch.
INSTALLATION:
a .
Solder wires to new switch, and remove tags. Connect wires so
t h a t o p e r a t i o n o f s w i t c h i n t e r r u p t s c o n t i n u i t y i n l i n e . U se
m u l t i m e t e r t o t e s t c o n t i n u i t y .
b.
Install momentary switch, and secure with nut. Aviod twisting
body as nut is tightened.
c .
Reinstall two cable clamps.
d .
Plug in power cord, and turn power ON.