TM 5-6675-324-14
9-16.5 Remove/Install Chemical Storage Cabinet.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: 1/4 in. Drive Socket Set
6 in. Extension, 1/4 in. Drive
11/32 in. Combination Wrench
Flat Tip Screwdriver
Cross Tip Screwdriver
SUPPLIES: Supply Cabinet
Remove bolts and washers holding cabinet to wall.
a.
Remove caps and lag bolts holding mounting bracket to floor and remove cabinet.
b.
Remove screws, lockwashers, and nuts and remove mounting brackets and spacers from cabinet.
c.
Retain mounting brackets and spacers for use on new cabinet.
Position spacers and mounting brackets on new cabinet, and install but do not tighten nuts,
d.
Place new cabinet in position, and install but do not tighten lag bolts.
e.
Secure cabinet to wall with washers and bolts.
f.
Tighten the bracket retaining bolts and nuts.
g.
Tighten the bolts holding the mounting brackets to the floor, and install the caps.
h.
9-11