TM 5-6675-324-14
t.
Set exposure control lever to 5.
u.
Set copy number display to 3.
v.
Press COPY START key after WAIT/STANDBY indicator stops flashing.
Adjust VR205 until same density as that of sample A is obtained.
w.
Turn power switch to O (OFF); then disconnect jumper wire.
x.
Turn power switch to 1 (ON).
y.
z.
Set copy number to 5.
Wait three minutes.
aa.
Press COPY START key.
ab.
Adjust VR205 carefully so that same density is obtained for first and
ac.
tenth copies.
Repeat steps z through ac as necessary.
ad.
Make a single copy. If it is different from the copy made in step 12,
ae.
carefully adjust VR206 as necessary.
Remove screwdriver from door switch and turn power switch to O (OFF).
af.
Reinstall dc controller cover.
ag.
Close front door.
ah.
3-20.4 Adjust Platen Brake.
MOS: 35E, Special Electronic Devices Repairer
TOOLS: No. 2 Cross Tip Screwdriver
1/8 in. x 2-1/2 in. Flat Tip Screwdriver
1/4 in. x 4 in. Flat Tip Screwdriver
Machinist's Rule
WARNING
Electrical shock hazard. You must stand on rubber matting as a protective
measure before performing this procedure. Death or serious injury could
result.
Turn power switch to O (OFF).
a.
3-141