TM 5-6675-324-14
OPERATION UNDER UNUSUAL CONDITIONS .
1-7.
NOTE
Damage to container permitting light leaks, water, or dirt entry must be
temporarily repaired using available material on hand. Maintenance person-
nel will conduct permanent repairs; however, crew must maintain operation-
al capability of section.
1-7.1 Operation in High Wind or Storm Conditions.
Relocate section if trees or structures present hazard.
a.
b. Secure section corners at lifting eyes to deadmen or substantial objects.
Remove all loose objects from area.
c.
1-7.2 Operation in Cold Weather.
a. The operation of the internal equipment is performed within environmentally
controlled conditions; however, in extreme cold, the main power supply cable and
ground cable, will become hard, brittle, and difficult to handle. Be careful
when connecting or disconnecting the cables so that kinks and unnecessary loops
will not result in permanent damage.
b. Make certain that connections and cable receptacles on the outside of the
section are free of frost, snow, and ice.
When section heaters are not operating or when the section is being trans-
ported, liquid consumable supplies may freeze, break their containers, then melt,
and ruin equipment or documents. Store these items in an area to prevent equipment
and document damage.
1-43