TM 5-6675-323-14
Remove fuse caps and fuses.
c.
d. Remove screws from cover on underside of crosspiece assembly.
Release strain relief bushing from power cord.
e.
f. Push sufficient power cord into crosspiece assembly to allow access to
terminal connectors.
Tag and disconnect wires from fuse holders and ground.
g.
h. Remove defective power cord through hole in crosspiece assembly.
Install new power cord through hole in crosspiece assembly.
i.
Connect wires to ground and fuse holders.
j.
k. Reinstall strain relief bushing on power cord.
Reinstall cover on underside of crosspiece assembly and secure with
l.
screws.
Reinstall fuses and fuse caps.
m.
Plug in below-stage illuminator cord.
n.
P l u g in power cord and turn power on.
o.
8-41