TM 5-6675-323-14
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
Turn off power switch.
a.
U n p l u g power cord.
b.
Unplug below-stage illuminator cord.
c.
Remove fuse caps and fuses.
d.
R e m o v e screws from cover on underside of crosspiece assembly. Move
e.
cover to allow access to power switch.
Remove locknut and washer securing power switch to control panel.
f.
R e m o v e power switch through underside of crosspiece assembly.
g.
Tag and disconnect wires from defective power switch.
h.
C o n n e c t wires to new power switch.
i.
Position power switch in crosspiece assembly.
j.
R e i n s t a l l washer and locknut securing power switch to control panel.
k.
R e i n s t a l l cover on underside of crosspiece assembly.
l.
R e i n s t a l l f u s e s and f u s e c a p s .
m.
P l u g in below-stage i l l u m i n a t o r
cord.
n.
Plug in power cord.
o.
T u r n power on.
p.
8-37