TM 5-6675-323-14
MOS: 41B, Topographic Instrument Repair Specialist
TOOLS: 9/64 in. Flat Tip Screwdriver
S o l d e r i n g Gun
SUPPLIES:
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing equipment.
NOTE
T h e same procedure is used to replace transformer T1 and T2.
a.
T u r n power off and unplug power cord.
b. Loosen screws and remove front cover.
c.
R e m o v e quick-disconnect from power panel.
d. Remove main power switch from backplate by releasing switch from bezel
retaining clip.
CAUTION
P o w e r panel must be supported when screws are removed from backplate.
Damage to equipment will result if power panel falls.
e.
R e m o v e screws from main power switch backplate.
f. Lower power panel.
R e m o v e screws securing back cover.
g.
6-70