TM 5-6675-323-14
4-2.3
Equipment
Data.
Width
6 0 in. (152.4 cm)
Depth
3 0 in. (76.2 cm)
Height
2 0 in. (50.8 cm)
Weight
2 5 8 lbs (117 kg)
Power
Requirements
120 V, 60 Hz, 7 amps
Leaf Light
Illuminated
Surface
1 0 in. X 17 in. (25.4 cm X
43.2 cm)
Light
Intensity
1 0 0 to 2000 ft lamberts
( 3 4 2 . 6 t o 6 8 5 2 c a n d e l a / m2)
Microscan
Mounting
Rotation with Positive Lock
90 degrees
Forward/Backward Movement
3 in. (7.62 cm)
TECHNICAL PRINCIPLES OF OPERATION.
4-3.
4-3.1 G e n e r a l .
a.
P l a t f o r m moves up and down under spring tension and supports microscan.
b. Turntable rotates microscan left or right.
Light operates only with leaf in the out position.
c.
Leaf light pulls in or out.
4-2