TM 5-6675-323-14
3-29.8 Electrostatic Table (Platen) Replacement.
MOS :
35E, Special Electronic Devices Repairer
TOOLS :
C r o s s Tip Screwdriver (No. 1)
SUPPLIES:
Platen
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing.
Turn off LINE power switch.
a.
R e m o v e power cord and HP-IB Interface.
b. To open up plotter:
(1) Unscrew two hood retaining screws and remove rear hood.
(2) Raise upper deck.
Swing latching bar up and engage it securely in
retaining slot.
3-274