TM 5-6675-323-14
Place the SELF TEST switch S4-2 in the ON position. Press RESET and
b.
t h e n press STEP.
S e t the X-MUTE S1 to the OFF position.
c.
P r e s s and hold the #4 PEN SELECT pushbutton for approximately five
d.
seconds.
Release.
Adjust the Y-3rd harmonic potentiometer R39 for minimum vibration
e.
of the pen holder.
P r e s s and hold the #5 PEN SELECT pushbutton until the plotter arm
f.
stops . Release.
Adjust the Y-gain potentiometer R27 for minimum vibration of the
g.
p e n holder.
h.
P r e s s and hold the #6 PEN SELECT pushbutton until the plotter arm
s t o p s . Release.
C e n t e r the Y-B offset potentiometer R44 and adjust the Y-A R47 for
i.
m i n i m u m vibration of the pen holder.
j.
Adjust the Y-B offset potentiometer R44 for minimum vibration of
the pen holder.
R e t u r n the X-MUTE switch S1 to the ON position. Also place the
k.
S E L F TEST switch to the OFF position.
Press RESET.
l.
m.
Lower upper deck assembly and reinstall rear hood.
3-265