TM 5-6675-323-14
Table 3-24. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8.
PLOTTER DOES NOT RESPOND TO COMMANDS OR GENERATES "ERROR" FOR EACH
INSTRUCTION - Cont
Step 10. Insert system test cartridge.
Press following keys in sequence:
STOP
ERASE
A
EXECUTE
RESET
1
d
b
3
EXECUTE
NOTE
Tape should load and printer should print message similar to following:
PLEASE VERIFY THE FOLLOWING:
GEN. I/0 ROM IN
EXT. I/0
ROM IN
ROM OUT
9862
9872
ROM IN
Message will vary depending on which ROM's are plugged into computer.
S t e p 11. Check that plotter ROM, general and extended 1/0 ROM's, are present
i n computer for the 9825A model.
Step 12. When computer display says ENTER MODEL # TO BE TESTED. ... press fol-
9, 8, 0, 3, 4, SHIFT and A, and
lowing keys in succession:
CONTINUE.
Step 13. When display says . . . ENTER SELECT CODE . . ., press CONTINUE.
3-238