TM 5-6675-323-14
Table 3-19. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
(Number) - Hundreds of Hours
AN - Annually
W - Weekly
B - Before
- Semiannally
S
M - Monthly
D-During
BI - Biennially
Q - Quarterly
A After
For Reediness
ITEM TO BE INSPECTED
Reporting,
IN-
Equipment Is
ITEM TER-
PROCEDURE
Not Ready/
NO. V A L
Available If:
GRAPHICS PLOTTER - Cont
Plotting Repeatability and Accuracy Test.
3
M
Load plotter with blank chart paper. Place new
1.
p e n in pen arm.
E n t e r program below into calculator and run
2.
R e c o r d program on tape for future
program.
use.
0:
fxd
0
V S;
pa 15000, 10000, 5000,
1 : wrt 705, " p u ;
6000;"
2: wrt 705, "vs1; pd; pr0,-500"
3 : w r t 7 0 5 , " p u ; pa0, 0, 5000, 5500;"
4: wrt 705, `pd; vs1; pr0, 250; vs; pu; pa0, 0"
5 : wrt 705, " v s ; p u ; p a 0 , 0 , 6 0 0 0 , 5 0 0 0 ; "
6: wrt 705, "pd; vs1; pr500, 0"
7 . w r t 7 0 5 , " p u ; pa 15000, 10000, 6500, 5000"
8: wrt 705, "pd; vs1; pr-250, 0; vs; pu; pa0, 0"
9: wrt 705, "t 11, 1; pu; pa0, 1000"
1 0 : for X=0 to 15200 by 400
11: wrt 705, "pd; pa", X,",1000; xt
1 2 : next X
1 3 : w r t 7 0 5 , " p u ; pa 1000, 0"
1 4 : for Y=0 to 10000 by 400
3-155