TM 5-6675-323-14
Function
Control or Indicator
P r e s s i n g either moves pen
S c a l i n g Point Control Push Buttons
to corresponding physical
p o i n t , P1 or P2, on pla-
t e n . When the plotter is
initialized, it sets P1
at lower left corner and
P 2 at upper right corner
Pressing
of platen.
E N T E R , P1, or P2 relo-
cates that scaling point
to current pen location.
Multi-purpose
button
with
ENTER Push Button
lamp:
Pushed before CHART HOLD,
it initializes plotter.
(lamp blinks.)
P u s h e d before P1 or
P2, it sets new
scaling points.
(lamp blinks.)
Used to enter point
in digitizing mode.
(lamp is steady.)
Used with pen select
buttons to store
pen in its stable.
NOTE
P u s h i n g any of pen
control arrows can-
cels ENTER lamp.
3-44