TM 5-6675-320-14
Table 4-24. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8 .
PLOTTER DOES NOT RESPOND TO COMMANDS OR GENERATES ERROR FOR EACH
INSTRUCTION - Cont
Step 14.
NOTE
Pressing CONTINUE specifies factory select code 705.
When computer disiplay says ENTER # OF TIMES TO RUN TEST . . . . enter
number (press corresponding key) for number of times you want to run
test and press CONTINUE.
NOTE
One test takes approximately 2 min to
than 10 times.
After each test is complete, computer
COMPLETE. Any errors that occur will
complete.
Do not run test more
w i l l d i s p l a y t i t l e o f t e s t a n d T E ST
b e p r i n t e d .-