TM 5-6675-320-14
Table 4-24. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. PLOTTER DOES NOT RESPOND TO COMMANDS OR GENERATES ERROR FOR EACH
INSTRUCTION - Cont
Step 10. Insert system test cartridge.
Press following keys in sequence:
STOP
ERASE
A
EXECUTE
RESET
d
3
EXECUTE
NOTE
Tape should load and printer should print message similar to following:
PLEASE VERIFY THE FOLLOWING:
GEN. I/O ROM IN
EXT. I/O ROM IN
9862
ROM OUT
9872
ROM IN
Message will vary depending on which ROMs are plugged into computer.
Step 11. Check that plotter ROM, general and extended I/O ROMs, are present
in computer for the 9825A model.
Step 12. When computer display says ENTER MODEL # TO BE TESTED..., press fol-
lowing keys in succession:
9, 8, 0, 3, 4, SHIFT and A, and
CONTINUE.
Step 13. When display says ...ENTER SELECT CODE..., press CONTINUE.
4-238
l
b