TM 5-6675-320-14
Table 4-24. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
NO PEN MOVEMENT IN Y DIRECTION
Step 1.
Open plotter.
Check position of Y-axis mute switch S2.
(a)
( b)
Step 2. Check
( a)
( b )
( c )
If S2 is turned off, proceed to step 2 .
Turn off S2.
fuses F3 and F4 on A2 for continuity.
If either is defective, replace fuse and turn S2 on.
If pen fails to move, replace A2 (paragraph 4-29.7).
If problem persists, replace Y-drive motor (paragraph
4 - 2 9 . 1 4 ).
5. PLOTTER INITIALIZES; OSCILLATES; THEN STOPS.
Step 1.
I n i t i a l i z e p l o t t e r u s i n g w r t 7 0 5,
IN program command and perform
X- and/or Y- limit switch adjustments (paragraph 4-29.9, 4-29.10)
t o c o r r e c t o s c i l l a t i o n s a t p o w e r - u p.
4-233