TM 5-6675-320-14
Table 4-22. TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13. PLOTTER WILL NOT RESPOND TO DIGITIZE COMMAND OR TRANSFER COORDINATES.
Step 1.
Check that LISTEN ONLY switch is set to 0 (talk and listen) mode.
(a) If not, set LISTEN ONLY switch to 0.
( b ) I f c o r r e c t , p r o c e e d t o s t e p 2 .
Step 2.
Check to see if ERROR or OUT OF LIMIT lamp on front panel is lit.
( a ) I f l i t , e n t e r c o r r e c t e r r o r i n p r o g r a m s y n t a x.
( b ) I f p r o b l e m p e r s i s t s , p r o c e e d t o s t e p 3 .
Step 3.
Perform operators HP-IB operational test (paragraph 4-14.2).
If problem persists, refer equipment to direct/general support
t r o u b l e s h o o t i n g .
4-19. MAINTENANCE PROCEDURES. There are no operator maintenance procedures
assigned for this equipment.
4-221