1-16.6 Replace Receptacle.
MOS: 83FJ6, Reproduction Equipment Repairer
41B, Topographic Instrument Repair Specialist
TOOLS :
Flat Tip Screwdriver
SUPPLIES:
Receptacle
WARNING
Death or serious injury may occur if receptacle circuit breaker is not turned
off before working on receptacle.
a.
T u r n o f f r e c e p t a c l e c i r c u i t b r e a k e r.
b. Remove cover plate screws.
c .
Remove cover plate.
d. Remove mounting screws.
e.
Withdraw receptacle to gain access to wires.
f. Loosen terminal screws and ground screw. Then
disconnect wires .
9.
Reconnect wires.
Connect green (ground) wire first.
1-72