TM 5-6675-319-14
Table 9-2.
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
NO APL OPERATION.
MACHINE WORKS NORMALLY IN SINGLE-PRINT OPERATION - Cont
Step 2.
Visually check APL fuse for
I f f i l a m e n t i s d e f e c t i v e,
3.
NO RPT OPERATION.
Step 1.
Check position of TRANSPORT
broken filament.
replace APL fuse (paragraph 9-10.4).
POWER switch.
(a) If TRANSPORT POWER switch is on, proceed to step 2.
(b) Turn on TRANSPORT POWER switch.
Step 2.
Visually check RPT fuse filament for defective filament.
If filament is defective, replace RPT fuse (paragraph 9-10.5).
4.
WHITE LAMP DOES NOT ILLUMINATE BUT MASTER POWER SWITCH IS ON.
Step 1.
Check position of SAFE/WHITE VIEW LIGHTS switch to WHITE position.
( a)
(b)
( c)
5.
SAFE LIGHT DOES
Turn SAFE/WHITE VIEW LIGHTS switch to WHITE position.
Replace white light (paragraph 9-10.2).
Refer to organizational maintenance.
NOT ILLUMINATE.
MASTER POWER SWITCH IS ON.
Step 1.
Check position of SAFE/WHITE VIEW light switch.
(a) If SAFE/WHITE VIEW LIGHTS switch is in the SAFE position,
proceed to step 2.
(b) Turn SAFE/WHITE VIEW LIGHTS switch to SAFE.
9-55