TM 5-6675-319-14
Table 5-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. ROLLERS OPERATE BUT BLOWERS DO NOT.
WARNING
Death or serious injury may occur from electrical shock unless power
cord is unplugged before servicing.
Step 1.
Check that two blower wire connectors in the plenum are connected
p r o p e r l y .
(a) If wires are properly connected, proceed to step 2.
( b ) R e c o n n e c t b l o w e r w i r e c o n n e c t o r s.
Step 2.
Check that wire connector from POWER switch to the two blower wires
is properly connected.
(a) If connection is properly made, proceed to step 3 .
(b) Reconnect wire connector.
Step 3.
Check for loose wire from POWER switch to blower connector.
Reattach wires.
5-30